START_INST_TAB  = P_CRE_CS
VERSION         = V00.03
DATE            = 94/01/26
AUTHOR          = I. Heinrichsen, L. Orsini
COMMENT
COMMENT ***************************************************************
COMMENT
COMMENT                         P_CRE_CS
COMMENT
COMMENT  Cold read-out electronics (CRE) check-out ranges and voltages 
COMMENT  for the C100, C200 and PHT-S detectors depending on the reset 
COMMENT  interval length RI. The off-sets are given in [V] the ranges 
COMMENT  are given as mnemonic as required by the PHT command.
COMMENT
COMMENT ***************************************************************
COMMENT
NUM_OF_KEYS     = 7
NUM_OF_ROWS     = 16
COMMENT --------------------------------------------------------
KEY_NAME01      = LOG2_RI
KEY_FORM01      = I
COMMENT --------------------------------------------------------
KEY_NAME02      = C100_CRE_RANGE
KEY_FORM02      = C
COMMENT --------------------------------------------------------
KEY_NAME03      = C100_CRE_OFFSET
KEY_FORM03      = F
COMMENT --------------------------------------------------------
KEY_NAME04      = C200_CRE_RANGE
KEY_FORM04      = C
COMMENT --------------------------------------------------------
KEY_NAME05      = C200_CRE_OFFSET
KEY_FORM05      = F
COMMENT --------------------------------------------------------
KEY_NAME06      = S_CRE_RANGE
KEY_FORM06      = C
COMMENT --------------------------------------------------------
KEY_NAME07      = S_CRE_OFFSET
KEY_FORM07      = F
COMMENT --------------------------------------------------------
COMMENT
COMMENT
COMMENT C100_CRE_RANGE     C200_CRE_RANGE       S_CRE_RANGE 
COMMENT          C100_CRE_OFFSET     C200_CRE_OFFSET   S_CRE_OFFSET 
COMMENT -----------------------------------------------------------------------
 7        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 6        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 5        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 4        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 3        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 2        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 1        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
 0        M0P25_VOLT  0.2370  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
-1        M0P25_VOLT  0.2350  M0P25_VOLT  0.2370  M0P25_VOLT  0.2370
-2        M0P25_VOLT  0.2310  M0P25_VOLT  0.2310  M0P25_VOLT  0.2310
-3        M0P25_VOLT  0.2190  M0P25_VOLT  0.2190  M0P25_VOLT  0.2190
-4        M0P25_VOLT  0.1970  M0P25_VOLT  0.1970  M0P25_VOLT  0.1970
-5        M0P25_VOLT  0.1500  M0P25_VOLT  0.1500  M0P25_VOLT  0.1500
-6        M0P25_VOLT  0.0500  M0P25_VOLT  0.0500  M0P25_VOLT  0.0500
-7        M0P25_VOLT  0.0500  M0P25_VOLT  0.0500  M0P25_VOLT  0.0500
-8        M0P25_VOLT  0.0500  M0P25_VOLT  0.0500  M0P25_VOLT  0.0500
END_INST_TAB


############################################################################
#
# Effective Revision History for P_CRE_CS
# Author: Luciano Orsini
# Creation Date: 09/03/94
#
# Version: $Id: p_cre_cs.txt,v 1.3 1994/11/15 08:35:16 ittlib Exp $
#

#
# Revision History: $Log: p_cre_cs.txt,v $
# Revision 1.3  1994/11/15  08:35:16  ittlib
# Update to logic to version 2.3
#
# Revision 3.3  1994/09/28  13:39:59  lorsini
# CRE-co voltages updated for use durig EE2.
# The ground based calibration data for the CRE co voltages were
# evaluated for the C100 detector and the data are now contained in the table
# for all three detectors with CRE-co voltage (C100, C200, PHT-S). That
# means that the asupmtion was made that the assemblies are are identical,
# w.r.t. their resitor pixel and their behaviour to the CRE-co voltages.
# The is a valid design asupmtion, but remains to be proven during EE2.
# The data are save from the operational point of view.
#
# note: The EE2 tests will be utilized to finalize this table,
#       it contains preliminary values extrapolated from the FM
#       data.
# 19.9.94, IH
#
# Revision 3.2  1994/07/19  13:04:16  lorsini
#    14.7.94
#   I. Heinrichsen: Table for use during EE1 test with FM instrument.
#                   At delivery date no data for the CRE co voltage were
#                   available for the FM, therefore everything is set to
#                   0.0 Volt which is a save value for the operation of PHT.
#
# Revision 3.1  1994/03/15  09:35:25  lorsini
# Development for EE1 test ( Initial Version ).
#
#