START_INST_TAB  = P_FC2_P3
VERSION         = VV5
DATE            = 96/04/12
AUTHOR          = B.Schulz
COMMENT
COMMENT ***************************************************************
COMMENT
COMMENT                        P_FC2_P3
COMMENT
COMMENT  Provides the transformation factors between power in W/mm^2 on
COMMENT  the P3 detector and the electrical power to be applied to
COMMENT  the fine calibration source FCS2 for this flux.
COMMENT  This relation is given for each P3 filter independently.
COMMENT  In addition the command mnemonic for the correct selection of the
COMMENT  thermal radiation source (trs) mode is given.
COMMENT
COMMENT ***************************************************************
COMMENT
NUM_OF_KEYS     = 5
NUM_OF_ROWS     = 45
COMMENT --------------------------------------------------------
KEY_NAME01      = FLUX
COMMENT         Flux in W/mm^2 on the P3 detector
KEY_FORM01      = F
COMMENT --------------------------------------------------------
KEY_NAME02      = ELECT_POWER_13
COMMENT         Electrical power in [mW] to be applied to FCS2 for filter
COMMENT         P3_60_UM
KEY_FORM02      = F
COMMENT --------------------------------------------------------
KEY_NAME03      = TRS_MODE_13
COMMENT         trs mode mnemonic to be used for the given flux for filter
COMMENT         P3_60_UM
KEY_FORM03      = C
COMMENT --------------------------------------------------------
KEY_NAME04      = ELECT_POWER_14
COMMENT         Electrical power in [mW] to be applied to FCS2 for filter
COMMENT         P3_100_UM
KEY_FORM04      = F
COMMENT --------------------------------------------------------
KEY_NAME05      = TRS_MODE_14
COMMENT         trs mode mnemonic to be used for the given flux for filter
COMMENT         P3_100_UM
KEY_FORM05      = C
COMMENT --------------------------------------------------------
COMMENT --------------------------------------------------------
COMMENT              60         100   
COMMENT
COMMENT   FLUX     13   M13   14   M14   
COMMENT -------------------------------------------------
1.78E-20 0.74 TRS2_ON 0.13 TRS2_ON
3.16E-20 0.79 TRS2_ON 0.15 TRS2_ON
5.62E-20 0.85 TRS2_ON 0.17 TRS2_ON
1.00E-19 0.92 TRS2_ON 0.19 TRS2_ON
1.78E-19 0.99 TRS2_ON 0.21 TRS2_ON
3.16E-19 1.06 TRS2_ON 0.24 TRS2_ON
5.62E-19 1.14 TRS2_ON 0.28 TRS2_ON
1.00E-18 1.24 TRS2_ON 0.32 TRS2_ON
1.78E-18 1.35 TRS2_ON 0.36 TRS2_ON
3.16E-18 1.47 TRS2_ON 0.42 TRS2_ON
5.62E-18 1.61 TRS2_ON 0.48 TRS2_ON
1.00E-17 1.76 TRS2_ON 0.56 TRS2_ON
1.78E-17 1.94 TRS2_ON 0.65 TRS2_ON
3.16E-17 2.14 TRS2_ON 0.77 TRS2_ON
5.62E-17 2.38 TRS2_ON 0.91 TRS2_ON
1.00E-16 2.65 TRS2_ON 1.08 TRS2_ON
1.78E-16 2.98 TRS2_ON 1.30 TRS2_ON
3.16E-16 3.38 TRS2_ON 1.57 TRS2_ON
5.62E-16 3.86 TRS2_ON 1.93 TRS2_ON
1.00E-15 4.47 TRS2_ON 2.40 TRS2_ON
1.78E-15 5.27 TRS2_ON 3.04 TRS2_ON
3.16E-15 6.36 TRS2_ON 3.94 TRS2_ON
5.62E-15 8.01 TRS2_ON 5.24 TRS2_ON
1.00E-14 11.11 TRS2_ON 7.30 TRS2_ON
1.78E-14 14.00 TRS2_ON 10.92 TRS2_ON
3.16E-14 14.00 TRS2_ON 19.11 TRS2_ON
5.62E-14 14.00 TRS2_ON 27.00 TRS2_ON
1.00E-13 14.00 TRS2_ON 27.00 TRS2_ON
1.78E-13 14.00 TRS2_ON 27.00 TRS2_ON
3.16E-13 14.00 TRS2_ON 27.00 TRS2_ON
5.62E-13 14.00 TRS2_ON 27.00 TRS2_ON
1.00E-12 14.00 TRS2_ON 27.00 TRS2_ON
1.78E-12 14.00 TRS2_ON 27.00 TRS2_ON
3.16E-12 14.00 TRS2_ON 27.00 TRS2_ON
5.62E-12 14.00 TRS2_ON 27.00 TRS2_ON
1.00E-11 14.00 TRS2_ON 27.00 TRS2_ON
1.78E-11 14.00 TRS2_ON 27.00 TRS2_ON
3.16E-11 14.00 TRS2_ON 27.00 TRS2_ON
5.62E-11 14.00 TRS2_ON 27.00 TRS2_ON
1.00E-10 14.00 TRS2_ON 27.00 TRS2_ON
1.78E-10 14.00 TRS2_ON 27.00 TRS2_ON
3.16E-10 14.00 TRS2_ON 27.00 TRS2_ON
5.62E-10 14.00 TRS2_ON 27.00 TRS2_ON
1.00E-09 14.00 TRS2_ON 27.00 TRS2_ON
1.78E-09 14.00 TRS2_ON 27.00 TRS2_ON
END_INST_TAB