Description Parameter: section 4.3.3
Processing Level: SPD
Usage in processing: section 7.3.1
File Type: Binary FITS Table
File Names: PP1RESETI, PP2RESETI, PP3RESETI,
PC1RESETI, PC2RESETI
In Derive_SPD, each signal is transformed to the equivalent signal for
a reference reset interval of 1/4 seconds. The Cal G files provide the
correction parameters A0 and A1 as defined in
section 7.3.1.
Field Offset Number Type Description PP1RESRI 0 1 I*4 Reset interval, n, with tRI=27-n s PP1RESDR 4 1 I*4 Data reduction factor PP1RESA0 4 1 R*4 Offset correction, A0 (V/s) PP1RESA1 4 1 R*4 Slope correction, A1 PP1RESE0 4 1 R*4 Error(standard deviation) in A0 (V/s) PP1RESE1 4 1 R*4 Error(standard deviation) in A1
ISOPHOT Data Users Manual, Version 4.1, SAI/95-220/Dc