Description Parameter: sections 5.6 and 5.7
Processing Level: AAR
Usage in processing: section 8.4.9 and 8.4.10
File Type: FITS Header
File Names: PFLUXCONV
The transmission of the whole optical path for each filter is characterized
by the parameter in m2Hz. The effective size of the
primary mirror, reflections,
filter transmission, spectral response of the detector, etc. are included.
The values for all filters are given in this calibration file.
PFLUXCONV is a FITS header without accompanying data. All entries have unit: .
Keyword Type Description FCP3P29 R conversion for PHT-P1 3.3 m filter FCP3P6 R conversion for PHT-P1 3.6 m filter FCP4P85 R conversion for PHT-P1 4.8 m filter FCP7P3 R conversion for PHT-P1 7.3 m filter FCP7P7 R conversion for PHT-P1 7.7 m filter FCP10 R conversion for PHT-P1 10 m filter FCP11P3 R conversion for PHT-P1 11.3 m filter FCP11P5 R conversion for PHT-P1 12 m filter FCP12P8 R conversion for PHT-P1 12.8 m filter FCP16 R conversion for PHT-P1 15 m filter FCP20 R conversion for PHT-P2 20 m filter FCP25 R conversion for PHT-P2 25 m filter FCP60 R conversion for PHT-P3 60 m filter FCP100 R conversion for PHT-P3 100 m filter FCC50 R conversion for C100 70 m filter FCC60 R conversion for C100 60 m filter FCC70 R conversion for C100 80 m filter FCC90 R conversion for C100 90 m filter FCC100 R conversion for C100 100 m filter FCC105 R conversion for C100 105 m filter FCC120 R conversion for C200 120 m filter FCC135 R conversion for C200 150 m filter FCC160 R conversion for C200 170 m filter FCC180 R conversion for C200 180 m filter FCC200 R conversion for C200 200 m filter FCC105 R conversion for C200 105 m filter
ISOPHOT Data Users Manual, Version 4.1, SAI/95-220/Dc