14.17 Wavelength Dependent Detector Flat-Fields


Description Parameter:	 Section 4.2.7
Processing Level:	 SPD
Usage in processing:	 Section 7.10.4
File Type:		 FITS Image
Units:			 Dimensionless
File Names:		 PC1FLAT, PC2FLAT

The responsivity of the individual detector pixels in the C100 and the C200 arrays vary from one filter to the other. These variations are different for different pixels in the array. Consequently, the flat-field of the array differs from one filter to the other. The flat-field is in principle calibrated out by the FCS measurement, but for multi-filter measurements where only 1 FCS measurement is taken, the flat-field correction must be applied when determining the fluxes in the filters in which the FCS was not taken.

For both detector flat-field calibration files the following FITS keywords are common: 
NAXIS = 3
TYPE = REAL*4


14.17.1 Product PC1FLAT: PHT C100 filter-to-filter flat-field correction


AXIS	Length	Description
1	9	C100 pixels, in same order as SPD.
2	7	filters: $\rm [CHWII~position-1]$ (see  Section A.1)
3	2	Correction and uncertainty


14.17.2 Product PC2FLAT: PHT C200 filter-to-filter flat-field correction


AXIS	Length	Description
1	4	C200 pixels in the same order as in SPD
2	5	Filters: $\rm [CHWII~position - 8]$ (see  Section A.1)
3	2	Correction and uncertainty